List of errors

Error 10 Boiler filling error - minimum boiler level not reached, maximum boiler level reached

Error 11 Cooking chamber heating element error

Error 12 Boiler filling error - maximum boiler level not reached

Error 13 Boiler filling error - minimum boiler level not reached

Error 15 Motor overheated

Error 16 Boiler heating element error

Error 17 Boiler emptying error - minimum level not released

Error 18 Boiler emptying error - maximum level not released

Error 26 Flap valve error

Error 31 Drain temperature sensor error

Error 32 Boiler temperature sensor error

Error 34 1-point core probe error

Error 35 Cooking chamber temperature sensor error

Error 36 6-point core probe error

Error 37 Electrical compartment temperature sensor error - thermistor disconnected

Error 38 Electrical compartment temperature sensor error - thermistor short

Error 40 Safety thermostat tripped

Error 41 Cooling error - electronics overheated

Error 42 Boiler overheated

Error 50 Pressure sensor error

Error 6x.1 Bootloader communication error

Error 6x.2 Relay board communication error

Error 6x.3 Frequency convertor 1 communication error

Error 6x.4 Frequency convertor 2 communication error

Error 6x.5 Hood communicateion error

Error 80.3 / 80.4 Frequency convertor 1 error - driver overheat

Error 81.3 / 81.4 Frequency convertor error - earth short-circuit

Error 82.3 / 82.4 Frequency convertor error - overvoltage

Error 83.3 / 83.4 Frequency convertor error - undervoltage

Error 84.3 / 84.4 Frequency convertor error - motor phase loss

Error 85.3 / 85.4 Frequency convertor error - motor overload

Error 86.3 / 86.4 Frequency convertor error - internal error

Error 87.3 / 87.4 Frequency convertor error - configuration error

Error 88.3 / 88.4 Frequency convertor error - modbus communication

Error 95 Blower 1 error

Error 96 Burner 1 error - flame ignition error

Error 97 Blower 2 error

Error 98 Burner 2 error - flame ignition error

Error 100 System error

Sd nOt FOUND SD card not detected

CrC Err. Software not uploaded

ELECTRICAL RESISTANCE OF VISION II COMPONENTS