Jump to content

Retigo/Error Codes

List of errors

Error 10 - Boiler filling error - minimum boiler level not reached, maximum boiler level reached

Error 11 - Cooking chamber heating element error

Error 12 - Boiler filling error - maximum boiler level not reached

Error 13 - Boiler filling error - minimum boiler level not reached

Error 15 - Motor overheated

Error 16 - Boiler heating element error

Error 17 - Boiler emptying error - minimum level not released

Error 18 - Boiler emptying error - maximum level not released

Error 26 - Flap valve error

Error 31 - Drain temperature sensor error

Error 32 - Boiler temperature sensor error

Error 34 - 1-point core probe error

Error 35 - Cooking chamber temperature sensor error

Error 36 - 6-point core probe error

Error 37 - Electrical compartment temperature sensor error - thermistor disconnected

Error 38 - Electrical compartment temperature sensor error - thermistor short

Error 40 - Safety thermostat tripped

Error 41 - Cooling error - electronics overheated

Error 42 - Boiler overheated

Error 50 - Pressure sensor error

Error 6x.1 - Bootloader communication error

Error 6x.2 - Relay board communication error

Error 6x.3 - Frequency convertor 1 communication error

Error 6x.4 - Frequency convertor 2 communication error

Error 6x.5 - Hood communicateion error

Error 80.3 / 80.4 - Frequency convertor 1 error - driver overheat

Error 81.3 / 81.4 - Frequency convertor error - earth short-circuit

Error 82.3 / 82.4 - Frequency convertor error - overvoltage

Error 83.3 / 83.4 - Frequency convertor error - undervoltage

Error 84.3 / 84.4 - Frequency convertor error - motor phase loss

Error 85.3 / 85.4 - Frequency convertor error - motor overload

Error 86.3 / 86.4 - Frequency convertor error - internal error

Error 87.3 / 87.4 - Frequency convertor error - configuration error

Error 88.3 / 88.4 - Frequency convertor error - modbus communication

Error 95 - Blower 1 error

Error 96 - Burner 1 error - flame ignition error

Error 97 - Blower 2 error

Error 98 - Burner 2 error - flame ignition error

Error 100 - System error

Sd nOt FOUND - SD card not detected

CrC Err. - Software not uploaded

Additional Information

ELECTRICAL RESISTANCE OF VISION II COMPONENTS

Article Name Resistance
AX00-0016 Space Heater Element 4,8 KW 3x 32 Ω
AX00-0045 Space Heater Element 1011-2011 v2 (18KW) 3x 8.5 Ω
AX00-047 Space Heater Element 611 v2 (10,3KW) 2x 14.2 Ω / 1x 17 Ω
AX24-0006 Boiler Heating Element 611 9 KW 3x 18 Ω
AX24-0008 Boiler Heating Element 12 KW 3x 13.3 Ω
EA10-0130 Thermistor 10k, 1m-Electrical Compartment 10.5 kΩ
EA11-0020 Motor 611-2021 v2 (NC) 3x 40 Ω
EA11-0024 Motor 623 v2 (NC) 170 Ω
EA12-0005 Pump Hanning 50 Hz 140 Ω
EA12-0010 Cleaning Pump 611-2011 V2 164 Ω
EA12-0011 Pump DPS 25-103-Drain Pump V2 86 Ω
EA12-0050 Double Solenoid Valve 2x 3.6 kΩ
EA12-0051 Simple Solenoid Valve 3.6 kΩ
EA12-0056 Triple Solenoid Valve 3x 3.6 kΩ
AX00-0018 208-404V Heater 1021,2021 3x 11 Ω
AX00-0055 480V Heater 623 3x 49.5 Ω
AX00-0058 480V Heater 611 2x 21 Ω / 1x 27 Ω
AX00-0056 480V Heater 721,1011,1221,2011 3x 11.7 Ω
AX00-0057 480V Heater 1021,2021
AC25-0306 Flap Valve Motor 4.4 Ω