Jump to content

Retigo/Error Codes: Difference between revisions

Started page
 
updates
 
Line 1: Line 1:
==List of errors==
==List of errors==
   
   
Error 10 Boiler filling error - minimum boiler level not reached, maximum boiler level reached
Error 10 - Boiler filling error - minimum boiler level not reached, maximum boiler level reached


Error 11 Cooking chamber heating element error
Error 11 - Cooking chamber heating element error


Error 12 Boiler filling error - maximum boiler level not reached  
Error 12 - Boiler filling error - maximum boiler level not reached  
   
   
Error 13 Boiler filling error - minimum boiler level not reached  
Error 13 - Boiler filling error - minimum boiler level not reached  
   
   
Error 15 Motor overheated
Error 15 - Motor overheated


Error 16 Boiler heating element error
Error 16 -  Boiler heating element error


Error 17 Boiler emptying error - minimum level not released
Error 17 - Boiler emptying error - minimum level not released
   
   
Error 18 Boiler emptying error - maximum level not released
Error 18 - Boiler emptying error - maximum level not released
   
   
Error 26 Flap valve error
Error 26 - Flap valve error
   
   
Error 31 Drain temperature sensor error
Error 31 - Drain temperature sensor error
   
   
Error 32 Boiler temperature sensor error
Error 32 - Boiler temperature sensor error
   
   
Error 34 1-point core probe error
Error 34 - 1-point core probe error
   
   
Error 35 Cooking chamber temperature sensor error
Error 35 - Cooking chamber temperature sensor error
   
   
Error 36 6-point core probe error
Error 36 - 6-point core probe error
   
   
Error 37 Electrical compartment temperature sensor error - thermistor disconnected
Error 37 - Electrical compartment temperature sensor error - thermistor disconnected
   
   
Error 38 Electrical compartment temperature sensor error - thermistor short
Error 38 - Electrical compartment temperature sensor error - thermistor short
   
   
Error 40 Safety thermostat tripped
[[Retigo/Error Codes/Error 40|Error 40]] - Safety thermostat tripped
   
   
Error 41 Cooling error - electronics overheated
Error 41 - Cooling error - electronics overheated
   
   
Error 42 Boiler overheated
Error 42 - Boiler overheated


Error 50 Pressure sensor error
Error 50 - Pressure sensor error


Error 6x.1 Bootloader communication error
Error 6x.1 - Bootloader communication error
   
   
Error 6x.2 Relay board communication error
Error 6x.2 - Relay board communication error
   
   
Error 6x.3 Frequency convertor 1 communication error
Error 6x.3 - Frequency convertor 1 communication error
   
   
Error 6x.4 Frequency convertor 2 communication error
Error 6x.4 - Frequency convertor 2 communication error
   
   
Error 6x.5 Hood communicateion error
Error 6x.5 - Hood communicateion error


Error 80.3 / 80.4 Frequency convertor 1 error - driver overheat
Error 80.3 / 80.4 - Frequency convertor 1 error - driver overheat
   
   
Error 81.3 / 81.4 Frequency convertor error - earth short-circuit  
Error 81.3 / 81.4 - Frequency convertor error - earth short-circuit  


Error 82.3 / 82.4 Frequency convertor error - overvoltage  
Error 82.3 / 82.4 - Frequency convertor error - overvoltage  


Error 83.3 / 83.4 Frequency convertor error - undervoltage  
Error 83.3 / 83.4 - Frequency convertor error - undervoltage  


Error 84.3 / 84.4 Frequency convertor error - motor phase loss  
Error 84.3 / 84.4 - Frequency convertor error - motor phase loss  


Error 85.3 / 85.4 Frequency convertor error - motor overload  
Error 85.3 / 85.4 - Frequency convertor error - motor overload  


Error 86.3 / 86.4 Frequency convertor error - internal error  
Error 86.3 / 86.4 - Frequency convertor error - internal error  


Error 87.3 / 87.4 Frequency convertor error - configuration error  
Error 87.3 / 87.4 - Frequency convertor error - configuration error  


Error 88.3 / 88.4 Frequency convertor error - modbus communication   
Error 88.3 / 88.4 - Frequency convertor error - modbus communication   


Error 95 Blower 1 error  
Error 95 - Blower 1 error  


Error 96 Burner 1 error - flame ignition error
Error 96 - Burner 1 error - flame ignition error


Error 97 Blower 2 error
Error 97 - Blower 2 error
   
   
Error 98 Burner 2 error - flame ignition error
Error 98 - Burner 2 error - flame ignition error


Error 100 System error
Error 100 - System error


Sd nOt FOUND SD card not detected
Sd nOt FOUND - SD card not detected


CrC Err. Software not uploaded  
CrC Err. - Software not uploaded  


ELECTRICAL RESISTANCE OF VISION II COMPONENTS
== Additional Information ==
'''ELECTRICAL RESISTANCE OF VISION II COMPONENTS'''
{| class="wikitable"
|+
!Article
!Name
!Resistance
|-
|AX00-0016
|Space Heater Element 4,8 KW
|3x 32 Ω
|-
|AX00-0045
|Space Heater Element 1011-2011 v2 (18KW)
|3x 8.5 Ω
|-
|AX00-047
|Space Heater Element 611 v2 (10,3KW)
|2x 14.2 Ω / 1x 17 Ω
|-
|AX24-0006
|Boiler Heating Element 611 9 KW
|3x 18 Ω
|-
|AX24-0008
|Boiler Heating Element 12 KW
|3x 13.3 Ω
|-
|EA10-0130
|Thermistor 10k, 1m-Electrical Compartment
|10.5 kΩ
|-
|EA11-0020
|Motor 611-2021 v2 (NC)
|3x 40 Ω
|-
|EA11-0024
|Motor 623 v2 (NC)
|170 Ω
|-
|EA12-0005
|Pump Hanning 50 Hz
|140 Ω
|-
|EA12-0010
|Cleaning Pump 611-2011 V2
|164 Ω
|-
|EA12-0011
|Pump DPS 25-103-Drain Pump V2
|86 Ω
|-
|EA12-0050
|Double Solenoid Valve
|2x 3.6 kΩ
|-
|EA12-0051
|Simple Solenoid Valve
|3.6 kΩ
|-
|EA12-0056
|Triple Solenoid Valve
|3x 3.6 kΩ
|-
|AX00-0018
|208-404V Heater 1021,2021
|3x 11 Ω
|-
|AX00-0055
|480V Heater 623
|3x 49.5 Ω
|-
|AX00-0058
|480V Heater 611
|2x 21 Ω / 1x 27 Ω
|-
|AX00-0056
|480V Heater 721,1011,1221,2011
|3x 11.7 Ω
|-
|AX00-0057
|480V Heater 1021,2021
|
|-
|AC25-0306
|Flap Valve Motor
|4.4 Ω
|}

Latest revision as of 23:30, 25 May 2025

List of errors

Error 10 - Boiler filling error - minimum boiler level not reached, maximum boiler level reached

Error 11 - Cooking chamber heating element error

Error 12 - Boiler filling error - maximum boiler level not reached

Error 13 - Boiler filling error - minimum boiler level not reached

Error 15 - Motor overheated

Error 16 - Boiler heating element error

Error 17 - Boiler emptying error - minimum level not released

Error 18 - Boiler emptying error - maximum level not released

Error 26 - Flap valve error

Error 31 - Drain temperature sensor error

Error 32 - Boiler temperature sensor error

Error 34 - 1-point core probe error

Error 35 - Cooking chamber temperature sensor error

Error 36 - 6-point core probe error

Error 37 - Electrical compartment temperature sensor error - thermistor disconnected

Error 38 - Electrical compartment temperature sensor error - thermistor short

Error 40 - Safety thermostat tripped

Error 41 - Cooling error - electronics overheated

Error 42 - Boiler overheated

Error 50 - Pressure sensor error

Error 6x.1 - Bootloader communication error

Error 6x.2 - Relay board communication error

Error 6x.3 - Frequency convertor 1 communication error

Error 6x.4 - Frequency convertor 2 communication error

Error 6x.5 - Hood communicateion error

Error 80.3 / 80.4 - Frequency convertor 1 error - driver overheat

Error 81.3 / 81.4 - Frequency convertor error - earth short-circuit

Error 82.3 / 82.4 - Frequency convertor error - overvoltage

Error 83.3 / 83.4 - Frequency convertor error - undervoltage

Error 84.3 / 84.4 - Frequency convertor error - motor phase loss

Error 85.3 / 85.4 - Frequency convertor error - motor overload

Error 86.3 / 86.4 - Frequency convertor error - internal error

Error 87.3 / 87.4 - Frequency convertor error - configuration error

Error 88.3 / 88.4 - Frequency convertor error - modbus communication

Error 95 - Blower 1 error

Error 96 - Burner 1 error - flame ignition error

Error 97 - Blower 2 error

Error 98 - Burner 2 error - flame ignition error

Error 100 - System error

Sd nOt FOUND - SD card not detected

CrC Err. - Software not uploaded

Additional Information

ELECTRICAL RESISTANCE OF VISION II COMPONENTS

Article Name Resistance
AX00-0016 Space Heater Element 4,8 KW 3x 32 Ω
AX00-0045 Space Heater Element 1011-2011 v2 (18KW) 3x 8.5 Ω
AX00-047 Space Heater Element 611 v2 (10,3KW) 2x 14.2 Ω / 1x 17 Ω
AX24-0006 Boiler Heating Element 611 9 KW 3x 18 Ω
AX24-0008 Boiler Heating Element 12 KW 3x 13.3 Ω
EA10-0130 Thermistor 10k, 1m-Electrical Compartment 10.5 kΩ
EA11-0020 Motor 611-2021 v2 (NC) 3x 40 Ω
EA11-0024 Motor 623 v2 (NC) 170 Ω
EA12-0005 Pump Hanning 50 Hz 140 Ω
EA12-0010 Cleaning Pump 611-2011 V2 164 Ω
EA12-0011 Pump DPS 25-103-Drain Pump V2 86 Ω
EA12-0050 Double Solenoid Valve 2x 3.6 kΩ
EA12-0051 Simple Solenoid Valve 3.6 kΩ
EA12-0056 Triple Solenoid Valve 3x 3.6 kΩ
AX00-0018 208-404V Heater 1021,2021 3x 11 Ω
AX00-0055 480V Heater 623 3x 49.5 Ω
AX00-0058 480V Heater 611 2x 21 Ω / 1x 27 Ω
AX00-0056 480V Heater 721,1011,1221,2011 3x 11.7 Ω
AX00-0057 480V Heater 1021,2021
AC25-0306 Flap Valve Motor 4.4 Ω